How do you measure wet film thickness on shop-applied organic zinc-rich primers to accurately predict dry film thickness?


Selected Answers

From Anthony Allegra of Sherwin-Williams on July 21, 2020:
I find that a slight drag of the wet film gauge, perpendicular to the gauge itself, moves the zinc- or flake-filled coating out of the way and allows direct contact of the outside notches to the substrate.

Please sign in to submit your answer this question    

Tagged categories: Asia Pacific; Coating Application; Dry Film Thickness (DFT); EMEA (Europe, Middle East and Africa); Latin America; North America