Problem Solving Forum

| More

October 7 - October 11, 2019

What measures must be taken to determine and assure the cleanliness of an abrasive?


Selected Answers

From Jeff Kim of Sherwin-Williams on October 18, 2019:
The short answer is there are 2 tests: ASTM D7393 - Standard Practice for Indicating Oil in Abrasives (vial test) and ASTM D4940 - Standard Test Method for Conductimetric Analysis of Water Soluble Ionic Contamination of Blast Cleaning Abrasives (conductivity test).

Please sign in to submit your answer this question    

Tagged categories: Abrasives; Surface Preparation; Surface preparation