Case Study: Stopping CUI with New High-Performance Epoxy Urethane System

TUESDAY, NOVEMBER 7, 2017

By Gary Whittaker, PE, Valentus Specialty Chemicals


One of the costliest corrosion problems faced by the chemical processing and petroleum refining industries is corrosion under insulation (CUI). CUI affects both carbon steel and stainless steel equipment and has been recognized as a problem for many years. The American Petroleum Institute publishes recommended practice API 583, “Corrosion Under Insulation and Fireproofing,” which provides information on the causes and mitigation of CUI. The National Association of Corrosion Engineers publishes SP0198, “Control of Corrosion Under Insulation and Fireproofing,” which provides information on the use of coatings to prevent CUI. In both documents, coatings play a major role in preventing CUI.

With its good moisture permeation and corrosion resistance, the system is an ideal choice for moderate temperature applications when the substrate is corroded and abrasive blasting is not practical.

Like its peer companies, Eastman Chemical Company has encountered CUI on both stainless steel and carbon steel equipment. Recently, Eastman began a program of CUI-related inspections and repairs to extend the life of several critical assets that operate under conditions that are conducive to CUI. Previous experience suggested that CUI was likely with an elevated temperature distillation column made of carbon steel. The column has been in service since the early 1980s with an operating temperature that varies from about 100 C at the base to 80 C at the top.

Operating requirements prevented shutdown of the column, so all coating and insulation work was completed while the column was in operation and the external surface was hot. When new, the equipment was painted with a red iron oxide primer and insulated with two inches of fiberglass blanket insulation. After more than 30 years of operation in an exposed outdoor location, the insulation was removed to permit a thorough external inspection, found damage was repaired and a protective coating system and new thermal insulation were installed.

As expected, when the old insulation was removed, corrosion of the steel substrate was found. It is very difficult to prevent the ingress of water through an aluminum jacket, particularly one that has many jacket penetrations — which is why corrosion to the shell occurred. Figure 1 shows typical corrosion damage found at an insulation support ring. Support rings are horizontal surfaces designed to provide vertical support for the thermal insulation. In this case, the ring was welded directly to the shell, which allowed water to accumulate in the insulation on the topside of the ring, resulting in corrosion of the steel shell.

Figure 1. CUI damage at insulation support ring

Historically, Eastman has used either epoxy phenolic or multi-polymeric coatings for CUI protection. In both cases the required surface preparation is abrasive blasting. Because this distillation column is in service, it was not possible to do abrasive blasting; instead an SP3 power tool-cleaned preparation was specified.

Valentus VSC1100, a high-quality, high-build, surface-tolerant aluminum epoxy mastic coating, was chosen for the first coat because of its outstanding corrosion resistance and tolerance of marginally prepared surfaces. VSC1200, a top coat with Eastman Tetrashield protective resin systems, was chosen for the second coat because of its demonstrated resistance to water permeation and chemicals.

Extensive laboratory testing carried out during the development of both coatings identified individual characteristics that provide each with properties that, when combined, produce a coating system with highly effective corrosion resistance. The Tetrashield resin, for example, was found to provide excellent resistance to water permeation and to many aggressive chemicals. These characteristics make the coating pair very useful in moderate-temperature CUI applications where an abrasive-blast surface preparation is not possible and in situations where the equipment cannot be taken out of service.

The laboratory testing also showed application of VSC1100 to a hot surface had no impact on the curing or properties of the coating. The hot surface temperature did require the addition of a cure blocker to ensure proper film characteristics for the VSC1200 topcoat. Figure 2 shows the VSC1100 as applied, and Figure 3 shows the VSC1200 topcoat.

Figure 2. Valentus VSC1100 applied to marginally prepared steel substrate at about 80 C

Figure 3. Valentus VSC1200 topcoat applied to the VSC1100 aluminum epoxy mastic at 80 C substrate temperature

Immersion-grade coating systems are chosen for CUI applications because they may be exposed to hot, wet conditions for extended periods. The high-build epoxy systems are only recommended for temperatures up to 60 C in NACE SP0198. Between 60 C and 150 C, NACE recommends epoxy phenolic coatings, which are considered immersion-grade coatings; however, in cases where the recommended abrasive blast cannot be done, the epoxy phenolic cannot be used. The Valentus system can bridge the temperature gap between 60 C and 150 C, given its good moisture permeation and corrosion resistance; however, it is not an immersion-grade system and should not be chosen in situations where continuous hot immersion is possible. The design of the insulation system should be done with CUI resistance in mind to help the coating system function as intended.

For the Eastman project, a moisture-resistant insulation was chosen, along with an elastomeric jacket material that is adhesively sealed to itself and to the vessel being insulated, as seen in Figure 4. This combination made it much less likely that water could get to and be held against the surface, thus reducing the need for moisture resistance in the coating system.

Figure 4. Top head of column with elastomeric jacket installed

*Claims or positions expressed by sponsoring authors do not necessarily reflect the views of TPC, PaintSquare or its editors.

ABOUT THE AUTHOR
Gary Whittaker, PE, Valentus Specialty Chemicals

Gary Whittaker retired in February 2018 from his roles as an Eastman Engineering fellow and a fellow of the Materials Technology Institute in the chemical process industry and is now a senior fellow, Materials Engineering, at Valentus Specialty Chemicals. He was employed by the Eastman Chemical Company since 1981 after earning BS and MS degrees in materials engineering at Virginia Tech. Whittaker is a licensed engineer in the state of Tennessee.

CONTACT AUTHOR | SEE ALL CONTENT FROM THIS SPONSOR

   

Advertisement

Technology Publishing Co., 1501 Reedsdale Street, Suite 2008, Pittsburgh, PA 15233

TEL 1-412-431-8300  • FAX  1-412-431-5428  •  EMAIL webmaster@paintsquare.com


The Technology Publishing Network

PaintSquare the Journal of Protective Coatings & Linings Paint BidTracker

 
EXPLORE:      JPCL   |   PaintSquare News   |   Interact   |   Buying Guides   |   Webinars   |   Resources   |   Classifieds
REGISTER AND SUBSCRIBE:      Free PaintSquare Registration   |   Subscribe to JPCL   |   Subscribe to PaintSquare News
MORE:      About PaintSquare.com   |   Privacy Policy (Updated 2/24/2020)   |   Terms & Conditions   |   Support   |   Site Map   |   Search   |   Contact Us