Problem Solving Forum (18)

Does roller nap decrease the lifespan of a three-coat OZEU (organic zinc prime coat, an epoxy intermediate coat, and a urethane finish coat) paint system? Is there a visual guide or specification for this in the industry or test results available for study?

What are the criteria for selecting coatings for application during extreme (atmospheric) heat?

If the walls of single-wythe CMU with core fill insulation become saturated, can they be adequately dried out for painting? If so, how?

What can be done to prevent rust bleed in crevices when applying a zinc/epoxy/urethane system?

What are the criteria for selecting coatings for application during extreme (atmospheric) heat?

What is the best way to ensure successful application of an acid stain to an existing horizontal concrete surface?

Where can I find industry standards for air quality during spray painting operations, specifically regarding moisture, oil and particulates?

Is it sufficient to specify simply that paint should be applied "according to the manufacturer’s instructions?" If not, what detail should be included?

How does one apply thin polymer coatings to installed tubes or pipes with diameters of one to three inches and lengths of 20 to 60 feet?

How do you prepare flame-cut edges for application of thermal spray metallic coatings? The problem is that these edges are often harder than the abrasive, so a very low profile is produced, resulting in lower-than-specified adhesion of the thermal spray to the steel.

What are some ways to improve transfer efficiency of airless spray application?

What differences in performance and speed do you see among plural-component, conventional airless, and conventional air spraying equipment for field painting structural steel?

How many times can a building be repainted before the paint becomes too thick to perform properly?

How long after blasting can stainless steel be left before painting? If this time is exceeded, what further surface preparation is required?

How do you adequately assess the adhesion of a newly applied coating?

How do you successfully apply a chemical-resistant lining to the interior of small-diameter pipes (3 inches or less)?

What is the effect on the permeability of a coating when you add additional coats, either at the time of the original painting or as a maintenance activity?

Is it sufficient to specify simply that paint should be applied "according to the manufacturer’s instructions?" If not, what kind of detail should be included?


Tarps manufacturing, Inc.
QUALITY MADE IN AMERICA —Available near you!

CLICK to get a behind-the-scenes look at how Tarps Manufacturing makes the highest-quality tarps right here in the USA — available nationwide.

Specialty Products, Inc. (SPI)
Polyurea & Polyurethane Spray Foam Training

SPI is committed to industry leading technical training for polyurea & polyurethane spray foam professionals. Attendees receive hands-on, in-depth training for using and troubleshooting plural-component equipment, spray guns, machine hoses & parts.

SABRE Autonomous Solutions
Safety, Productivity, Quality. Robotic Blasting

Learn how this simple to use, field deployed, automatic robot is eliminating hazards in major confined, cluttered and complex surface preparation projects.

Novetas Solutions
Safer Abrasive! 100% Recycled Glass!

NO Free Silica, Beryllium or other human Toxins! Great White Metal Finish and safer than Slags!
Call us at 866-775- 6226

Waterjet Technology Association (WJTA)
2016 WJTA-IMCA Expo Nov. 2-3, New Orleans

See the latest advances in automated and handheld UHP waterjetting tools/systems for paint/coating removal, surface prep, industrial cleaning. Exhibits, live demos.

Desco Mfg. Co., Inc.

Steel Fabrication

• Shipyards
• Plate Fabrication
• Structural Steel
• Maintenance

DESCO Mfg.Co., Inc.

HoldTight Solutions Inc.

Our HoldTight®102 salt remover & flash rust
preventer prevents flash
rust by removing surface contaminants. Contact us
for your nearest distributor.
(800) 319.8802

Humidity & Temperature Control Equipment

Rental Desiccant Dehumidifiers, ArcticDRY Units, Air Conditioners, Heaters and Generators to help control the climate on your next industrial painting project. Nationwide locations, 24/7 service: (866) 379-2600”

Montipower, Inc.
The MBX Bristle Blaster

Get a 2.7 to 3.3 mil profile and a Near White Metal Clean. For info visit or call 877 629-8777

PreTox Products - NexTec, Inc.
GOT LEAD? Specify Pretox System products

The ONLY Lead Stabilizer Compatible with All Paint Removal Methods. Works with all Blast Media: Grits | Recyclable Abrasives | CO2 | Water | Power Tools | Etc. Call Dave Steffen at 800.338.8296.

Technology Publishing

The Technology Publishing Network

The Journal of Protective Coatings & Linings (JPCL) PaintSquare
Durability + Design Paint BidTracker

EXPLORE:      JPCL   |   PaintSquare News   |   Interact   |   Buying Guides   |   Webinars   |   Resources   |   Classifieds
REGISTER AND SUBSCRIBE:      Free PaintSquare Registration   |   Subscribe to JPCL   |   Subscribe to PaintSquare News
MORE:      About   |   Privacy policy   |   Terms & conditions   |   Site Map   |   Search   |   Contact Us

© Copyright 2000-2016, Technology Publishing / PaintSquare, All rights reserved
2100 Wharton Street, Suite 310, Pittsburgh PA 15203-1951; Tel 1-412-431-8300; Fax 1-412-431-5428; E-mail