PaintSquare.com
      | Connect Follow us on Twitter Like us on Facebook
About | Subscribe | Advertise
  

 

Download our free e-book! Quality Control

 

Standards (11)


Standard Test Method for Adhesion of Organic Coatings by Scrape Adhesion

issued by ASTM

4.1 Coatings to perform satisfactorily must adhere to the substrates on which they are applied....


SSPC-PA 15, Method for Preparing Steel Test Panels for Evaluation of Coating Performance

issued by SSPC

This method standardizes materials and preparation requirements for steel test panels used for ...


SSPC-PA 16, Method for Evaluating Scribe Undercutting of Exposed Steel Test Panels

issued by SSPC

The standard establishes a procedure for evaluating rust undercutting on scribed coated steel t...


Standard Specification for Standard Environment for Conditioning and Testing Paint, Varnish, Lacquer, and Related Materials

issued by ASTM

This specification defines standard environment for normal conditioning and testing of paint, v...


Standard Practice for Testing Water Resistance of Coatings in 100% Relative Humidity

issued by ASTM

Water can cause the degradation of coatings, so knowledge of how a coating resists water is hel...


Standard Guide to Testing Solvent-Borne Architectural Coatings

issued by ASTM

This guide covers the selection and use of procedures for testing solvent-borne architectural c...


Standard Practice for Field Identification of Coatings

issued by ASTM

Information about the generic type of coating on a surface is required to select compatible coa...


Standard Practice for Testing Water Resistance of Coatings Using Water Immersion

issued by ASTM

Immersion in water can cause the degradation of coatings. Knowledge on how a coating resists wa...


Standard Test Method for Determining the Resistance of Paint Films and Related Coatings to Algal Defacement

issued by ASTM

Defacement of paint and coating films by algal growth is a common phenomenon under certain cond...


Standard Test Method for Measuring Total Water and Volatiles in Liquid Coatings Which Produce Cure Water Upon Heating

issued by ASTM

1.1 This test method is designed to measure total water which includes cure water resulting fro...


Standard Test Method for Porosity in Metallic Coatings by Humid Sulfur Vapor (“Flowers-of-Sulfur”

issued by ASTM

1.1 This standard covers equipment and test methods for determining the porosity of metallic co...


 
 
   

Tarps manufacturing, Inc.
QUALITY MADE IN AMERICA —Available near you!

CLICK to get a behind-the-scenes look at how Tarps Manufacturing makes the highest-quality tarps right here in the USA — available nationwide.


N.T. Ruddock Co.

Our Abrasives Hold Up Under Pressure

N. T. Ruddock focuses on abrasive selection, equipment evaluation, equipment maintenance & reduction of abrasive consumption. Other services include Screen Analysis & Background Radiation Testing.


Specialty Products, Inc. (SPI)
Polyurea & Polyurethane Spray Foam Training

SPI is committed to industry leading technical training for polyurea & polyurethane spray foam professionals. Attendees receive hands-on, in-depth training for using and troubleshooting plural-component equipment, spray guns, machine hoses & parts.


Novatek Corporation
Novatek Corporation, Dustless Coatings Removal

Strip, clean and profile all dust free! Comply with new lead standards. Contact today: (866) 563-7800


KTA-Tator, Inc. - Corporate Office
KTA Online
Instrument Catalog

• Any Manufacturer
• Any Instrument
• Any Time
Visit www.ktagage.com
Or call 800-582-4243


SSPC: The Society for Protective Coatings
http://www.sspc.org/

Join SSPC and Enhance
Your Career !


Versaflex Inc.
Best ANSI/NSF 61.5 Approved Potable Water Polyurea

VersaFlex Polyurea Earns Highest ANSI/NSF 61.5 Rating for High Temp Service, Minimum Tank Size and Max Thickness. Watch this FREE Webinar Today! Call 800-321-0906


NLB Corporation
Handheld VertaJet for concrete or steel

Ergonomic VertaJet from NLB boosts surface prep productivity. See how rotating 40,000 psi water jets strip a 6” path and get into corners, with vacuum recovery.


Sidewinder/Persyst Enterprises, Inc.
The Sidewinder Model M2 Solvent Recycler

Combat the rising cost of gunwash, thinners, acetone & more while drastically reducing waste disposal coat.


HoldTight Solutions Inc.
NO FLASH RUST -
NO CONTAMINANTS

Our HoldTight®102 salt remover & flash rust preventer prevents flash
rust by removing surface contaminants. It has no equal; only wannabees.
Contact us for your
nearest distributor.
(800) 319.8802 sales@holdtight.com

 
Technology Publishing

The Technology Publishing Network

The Journal of Protective Coatings & Linings (JPCL) PaintSquare
Durability + Design Paint BidTracker

 
EXPLORE:      JPCL   |   PaintSquare News   |   Interact   |   Buying Guides   |   Webinars   |   Resources   |   Classifieds
REGISTER AND SUBSCRIBE:      Free PaintSquare Registration   |   Subscribe to JPCL   |   Subscribe to PaintSquare News
MORE:      About PaintSquare.com   |   Privacy policy   |   Terms & conditions   |   Site Map   |   Search   |   Contact Us
 

© Copyright 2000-2016, Technology Publishing / PaintSquare, All rights reserved
2100 Wharton Street, Suite 310, Pittsburgh PA 15203-1951; Tel 1-412-431-8300; Fax 1-412-431-5428; E-mail webmaster@paintsquare.com