Problem Solving Forum (20)


In reviewing the testing data for adhesion, some manufacturers indicate ASTM D4541 results while others show ASTM C3359 results. Is it possible to compare one against the other? For example, does 1037 psi provide better adhesion than 4A?


When performing maintenance surveys on structures that require coatings under insulation, how do you inspect the condition of the coatings?


What is the risk of damaging a paint film by inspecting a repaired area more than twice with a high-voltage holiday detector?


What errors are most likely to occur when measuring dry film thickness on steel, and how can I avoid them?


What tests and criteria can a coatings user specify to assure consistent lot-to-lot performance of supplied coatings?


Where are errors most likely to occur when measuring dry film thickness on steel, and how can they be avoided?


For coatings with a high-solids content (95 percent or more), what kinds of defects, such as holidays or micropores, are possible or likely to occur in the applied film? How can these be prevented or remedied?


Why would a pull-off adhesion test give a high value (no failure) for a solventless epoxy that later showed poor adhesion in service?


How do you accurately measure the adhesion of inorganic zinc?


How does the concave or convex curvature of a surface affect the dry film thickness reading?


In what circumstances is third-party inspection recommended for commercial coating work?


How does the concave or convex curvature of a surface affect the dry film thickness reading?


How do you adequately assess the adhesion of a newly applied coating?


What can be done to prevent rust bleed in crevices when applying a zinc/epoxy/urethane system?


How do you assess vertical concrete surface pH after surface preparation of existing concrete?


What is the best way to assure compliance with specified dry film coating thickness requirements on vertical concrete?


As a facility owner, how can I justify the cost of quality control measures, such as third-party inspection, to upper management in my company?


What tests and criteria can a coatings user specify to assure consistent lot-to-lot performance of supplied coatings?


As a facility owner, how can I justify the cost of quality control measures, such as third-party inspection, to upper management in my company?


What quality control checks can I use to assure the cleanliness of steel abrasive in a fabricator's or shipyard's shop?


 
 
   

**Commercial white papers, product videos, and other sponsored documents posted on this site are paid content from third-party companies; inclusion and posting on this site does not imply an endorsement nor recommendation of the content by Technology Publishing/PaintSquare. By signing in and viewing or downloading this paid content, you agree to make your name and full contact information available to the sponsor of the content.

Advertisements
 
SABRE Autonomous Solutions
 
Quality
 
The ALPHA1 provides a consistent finish day-in
day-out; job to job.
 

 
Detail Masters
 
Overspray Removal
 
We offer professional, turnkey service and unparalleled quality!
Our process can save hundreds— even thousands of dollars. It's fast, environmentally safe and 100% guaranteed.
 

 
SEMicro Division, M.E. Taylor Engineering, Inc.
 
Coatings Adhesion Testers
 
The PATTI® accurately measures the bond strength between coating & substrate. Outfitted properly, the surface can be rough, porous, or curved & >10K psi strong!
 

 
SAFE Systems, Inc.
 
Portable Dust Collectors for Tough Environments
 
Trailer and skid-mounted models in numerous sizes, powered by electric and/or diesel. Sloped roofs, multiple dust inlets, high static, dampered fans. Lockable power & drive compartments.
 

 
BASF
 
New resins from BASF will have metals loving water!
 
Excellent corrosion resistance, low VOC, high gloss, thin films www.basf.us/industrialcoatings dpsolutions@basf.com 800-231-7868
 

 
NLB Corporation
 
NLB Sure Shroud: Greater Protection and Flexibility
 
NLB’s Sure Shroud’s lighter weight and flexibility reduces operator fatigue and offers unmatched protection against high pressure hose ruptures. 10k to 40k psi rated.
 

 
CHLOR*RID International Inc.
 
SOLUTIONS THAT WORK
 
Companies that invest in corrosion control use CHLOR RID products
  • Soluble salt removal liquid
  • Test kits to verify contamination levels
  • Surface passivation to hold the blast
INFO@CHLOR-RID.COM 800.422.3217
 

 
Strategic Materials Inc.
 
Coming April 2017
 
Available April 2017. TruAbrasives™, a clean crushed glass abrasive superior to other abrasives for performance, health, and environmental benefits.
 

 
Monti Tools, Inc.
 
BRISTLE BLASTER® – THE ORIGINAL ONE
 
  • Abrasive blast with a power tool
  • Remove corrosion, mill scale and coatings
  • Cleans & roughens
  • Meets SSPC-SP 10 / NACE No. 2
  • Profile up to 4.7 mils
  • ATEX Zone 1
  •  

     
    US Minerals
     
    Hit Harder. Clean Faster.
     
    Black Diamond abrasive products are the toughest, most effective blasting media and supply the superior power you need to get any job done.
     

     

    Technology Publishing Co., 1501 Reedsdale Street, Suite 2008, Pittsburgh, PA 15233

    TEL 1-412-431-8300  • FAX  1-412-431-5428  •  EMAIL webmaster@paintsquare.com


    The Technology Publishing Network

    Durability + Design PaintSquare the Journal of Protective Coatings & Linings Paint BidTracker

     
    EXPLORE:      JPCL   |   PaintSquare News   |   Interact   |   Buying Guides   |   Webinars   |   Resources   |   Classifieds
    REGISTER AND SUBSCRIBE:      Free PaintSquare Registration   |   Subscribe to JPCL   |   Subscribe to PaintSquare News
    MORE:      About PaintSquare.com   |   Privacy policy   |   Terms & conditions   |   Site Map   |   Search   |   Contact Us