SSPC-PS Guide 7.00, Guide for Selecting One-Coat Shop Painting Systems

All Standards | SSPC Standards
Search Standards


Click to Purchase and Download this Standard or Test Method

Revision Date: November 01, 1982
Updated On: April 01, 2002
Editorial Change: November 1, 2004
 
This guide covers one-coat shop painting systems for steel that will not be exposed to corrosive conditions for long periods. They are also suitable for steel encased in concrete in those cases where bonding of steel to concrete is not required. They can be used under fireproofing.

These systems are suitable for use on parts or structures exposed in Environmental Zones 0 (encased in concrete or masonry, normally dry)and 1A (interior, normally dry).

COMMENT: These one-coat painting systems are not expected to protect steel exposed to the weather for periods longer than six months in normal rural and industrial areas and for even shorter exposure periods for heavy industrial or marine exposures. They can be used on open frames or structural steel in buildings not subjected to high humidity, condensation, or corrosive fumes.

The paints covered by this guide are primers, and if a color other than the standard color is required, then the color must be specified.

(Back to all Standards)

 
   

able equipment rental
RENTALS | SALES | SERVICE | PARTS

Construction equipment, plus compressors up to 1,800 cfm of air power & a fleet of service vehicles providing repairs to customer owned fleets. 866-468-2666.
www.ableequipment.com


Novetas Solutions
Abrasive Blasting near or over water?

100% Recycled Glass! NO Arsenic, Beryllium or other Toxic Metals! Great White Metal Finish and Safer than Slags! Call us at 866-775-6226


CHLOR*RID International Inc.
Hold*Blast

*Provides outstanding
  performance
*Easy to use and only pennies
  per square foot
*Works with poor quality
  water
*Use for mist blasting, vapor
  blasting, wet blasting and
  UHP WJ
*Leaves no residue and
  provides excellent adhesion.
  www.chlor-rid.com


HoldTight Solutions Inc.
NO FLASH RUST - NO CONTAMINANTS

Our HoldTight®102 salt remover & flash rust
preventer prevents flash
rust by removing surface contaminants. Contact us
for your nearest distributor.
(800) 319.8802 sales@holdtight.com


SEMicro Division, M.E. Taylor Engineering, Inc.
Coatings Adhesion Testers

The PATTI® accurately measures the bond strength between coating & substrate. Outfitted properly, the surface can be rough, porous, or curved & >10K psi strong!


Advanced Recycling Systems
ADVANCED RECYCLING SYSTEMS (ARS)

Recycling Machines, Dust Collectors, Rapid Deployment units are time-tested and approved for the rugged industrial environment. Contact ARS today!
(330)536-8210


NACE International, The Corrosion Society
Power On

Extend the life of your generation, transmission, and distribution systems by learning how to integrate corrosion control into your asset management plan.

 
 
 
Technology Publishing

The Technology Publishing Network

The Journal of Protective Coatings & Linings (JPCL) PaintSquare
Durability + Design Paint BidTracker

 
EXPLORE:      JPCL   |   PaintSquare News   |   Interact   |   Buying Guides   |   Webinars   |   Resources   |   Classifieds
REGISTER AND SUBSCRIBE:      Free PaintSquare Registration   |   Subscribe to JPCL   |   Subscribe to PaintSquare News
MORE:      About PaintSquare.com   |   Privacy policy   |   Terms & conditions   |   Site Map   |   Search   |   Contact Us
 

© Copyright 2000-2016, Technology Publishing / PaintSquare, All rights reserved
2100 Wharton Street, Suite 310, Pittsburgh PA 15203-1951; Tel 1-412-431-8300; Fax 1-412-431-5428; E-mail webmaster@paintsquare.com