G95 Standard Test Method for Cathodic Disbondment Test of Pipeline Coatings (Attached Cell Method)

All Standards | ASTM Standards
Search Standards


Click to Purchase and Download this Standard or Test Method

Revision Date: July 08, 2013
Updated On: July 10, 2013
Editorial Change:
 
4.1 Damage to pipe coating is almost unavoidable during transportation and construction. Breaks or holidays in pipe coatings may expose the pipe to possible corrosion since, after a pipe has been installed underground, the surrounding earth will be moisture-bearing and will constitute an effective electrolyte. Applied cathodic protection potentials may cause loosening of the coating, beginning at holiday edges. Spontaneous holidays may also be caused by such potentials. This test method provides accelerated conditions for cathodic disbondment to occur and provides a measure of resistance of coatings to this type of action.

4.2 The effects of the test are to be evaluated by physical examinations and monitoring the current drawn by the test specimen. Usually there is no correlation between the two methods of evaluation, but both methods are significant. Physical examination consists of assessing the effective contact of the coating with the metal surface in terms of observed differences in the relative adhesive bond. It is usually found that the cathodically disbonded area propagates from an area where adhesion is zero to an area where adhesion reaches the original level. An intermediate zone of decreased adhesion may also be present.

(Back to all Standards)

 
   

Elcometer, Inc.
Elcometer 106 Pull-Off Adhesion Tester

Portable, easy to operate; Provides numerical value for adhesion; Comes in carrying case - Ideal for site tests; No power supply necessary.


Atlantic Design, Inc.
MORE THAN JUST A SALES PITCH!

Simplicity! Dependability! Safety! We’ve built these features into every cleverly engineered inch of our newest models. It’s all there. 866.Call.ADI


Van Air Systems
The Blast Pak

Van Air Systems' portable desiccant air dryer. Get dry compressed air with this All-In-One blasting and coating solution.


CS Unitec
Peening Preparation Tools

CS Unitec’s hand-held scarifiers are an ideal alternative to small-area shot blasting for cleaning and preparing concrete & metal surfaces. info@csunitec.com


Termarust Technologies
Termarust (HR CSA) Chemically Stops
Active Corrosion

Truss bridge treated with Termarust's (HR CSA) in 1995. This highway & rail truss bridge is still stable and there still is no active corrosion.


SSPC: The Society for Protective Coatings
http://www.sspc.org/

Join SSPC and Enhance
Your Career !


KTA-Tator, Inc. - Corporate Office
KTA Analyzes
Coating Failures

• Field Diagnosis
• Lab Diagnosis
• Determination of Cause
• Recommendations
www.kta.com
800-245-6379

 
 
 
Technology Publishing

The Technology Publishing Network

The Journal of Protective Coatings & Linings (JPCL) PaintSquare
Durability + Design Paint BidTracker JPCL Europe

 
EXPLORE:      JPCL   |   PaintSquare News   |   Interact   |   Buying Guides   |   Webinars   |   Resources   |   Classifieds
REGISTER AND SUBSCRIBE:      Free PaintSquare Registration   |   Subscribe to JPCL   |   Subscribe to PaintSquare News
MORE:      About PaintSquare.com   |   Privacy policy   |   Terms & conditions   |   Site Map   |   Search   |   Contact Us
 

© Copyright 2000-2014, Technology Publishing / PaintSquare, All rights reserved
2100 Wharton Street, Suite 310, Pittsburgh PA 15203-1951; Tel 1-412-431-8300; Fax 1-412-431-5428; E-mail webmaster@paintsquare.com