G95 Standard Test Method for Cathodic Disbondment Test of Pipeline Coatings (Attached Cell Method)

All Standards | ASTM Standards
Search Standards


Click to Purchase and Download this Standard or Test Method

Revision Date: July 08, 2013
Updated On: July 10, 2013
Editorial Change:
 
4.1 Damage to pipe coating is almost unavoidable during transportation and construction. Breaks or holidays in pipe coatings may expose the pipe to possible corrosion since, after a pipe has been installed underground, the surrounding earth will be moisture-bearing and will constitute an effective electrolyte. Applied cathodic protection potentials may cause loosening of the coating, beginning at holiday edges. Spontaneous holidays may also be caused by such potentials. This test method provides accelerated conditions for cathodic disbondment to occur and provides a measure of resistance of coatings to this type of action.

4.2 The effects of the test are to be evaluated by physical examinations and monitoring the current drawn by the test specimen. Usually there is no correlation between the two methods of evaluation, but both methods are significant. Physical examination consists of assessing the effective contact of the coating with the metal surface in terms of observed differences in the relative adhesive bond. It is usually found that the cathodically disbonded area propagates from an area where adhesion is zero to an area where adhesion reaches the original level. An intermediate zone of decreased adhesion may also be present.

(Back to all Standards)

 
   

Axxiom Manufacturing
Schmidt Introduces
the New miniBRS

Reduced in size, it is incredibly easy to maneuver and operate! The perfect alternative to larger blast & recovery units when project space is limited.
Call 1-800-231-2085


U.S. Zinc

Combat deterioration and corrosion with our zinc dust in your paints and coatings. U.S. Zinc – Helping the world work™


Modern Safety Techniques
Modern Safety Techniques

With our unique LTCat, we can help to provide clean, safe breathing air to your workers. Take a look at our Breathing Air Systems, we supply at least twice as much charcoal as our competitors! Modern


Advanced Recycling Systems
ADVANCED RECYCLING SYSTEMS (ARS)

Recycling Machines, Dust Collectors, Rapid Deployment units are time-tested and approved for the rugged industrial environment. Contact ARS today!
(330)536-8210


Atlantic Design, Inc.
GOING PLACES YOU ONLY DREAM ABOUT!

We custom design.
We sell new & used.
We upgrade.
We retrofit.
We rent.
What are your equipment needs?
Cleverly simple. Clearly ADI. 866.Call.ADI


Dampney Co., Inc.
Solar Coating

High Temperature Resistant for Solar Panels/Collectors/Tubes. Achieve selectivity with the economy and ease
of application of a paint.


Elcometer, Inc.
Elcometer 266
DC Holiday Detector

Easily Finds Pinholes, Flaws & Thin Spots; Safer, More Reliable Testing; Voltage-Adjustable Keypad; Dual-Safety Switch On Handle.

 
 
 
Technology Publishing

The Technology Publishing Network

The Journal of Protective Coatings & Linings (JPCL) PaintSquare
Durability + Design Paint BidTracker JPCL Europe

 
EXPLORE:      JPCL   |   PaintSquare News   |   Interact   |   Buying Guides   |   Webinars   |   Resources   |   Classifieds
REGISTER AND SUBSCRIBE:      Free PaintSquare Registration   |   Subscribe to JPCL   |   Subscribe to PaintSquare News
MORE:      About PaintSquare.com   |   Privacy policy   |   Terms & conditions   |   Site Map   |   Search   |   Contact Us
 

© Copyright 2000-2014, Technology Publishing / PaintSquare, All rights reserved
2100 Wharton Street, Suite 310, Pittsburgh PA 15203-1951; Tel 1-412-431-8300; Fax 1-412-431-5428; E-mail webmaster@paintsquare.com