G62 Standard Test Methods for Holiday Detection in Pipeline Coatings

All Standards | ASTM Standards
Search Standards


Click to Purchase and Download this Standard or Test Method

Revision Date: July 08, 2013
Updated On: July 10, 2013
Editorial Change:
 
5.1 Method A—Method A describes a quick, safe method for determining if pinholes, voids, or metal particles are protruding through the coating. This method will not, however, find any thin spots in the coating. This method will determine the existence of any gross faults in thin-film pipeline coatings.

5.2 Method B—Method B describes a method for determining if pinholes, voids, or metal particles are protruding through the coating, and thin spots in pipeline coatings. This method can be used to verify minimum coating thicknesses as well as voids in quality-control applications.

(Back to all Standards)

 
   

Polyval Coatings
Polyflex® Polyurea Linings

exhibit outstanding versatility in use; providing abrasion resistance, superior seamless waterproofing and high-chem corrosion protection. www.polyflexlinings.com


DRYCO
Environmental Controls
Equipment & Service

Temporary climate control equipment. Dehumidifiers,
Heaters, A/C, Power, More…
Toll Free: 866-379-2600


Atlantic Design, Inc.
GOING PLACES YOU ONLY DREAM ABOUT!

We custom design.
We sell new & used.
We upgrade.
We retrofit.
We rent.
What are your equipment needs?
Cleverly simple. Clearly ADI. 866.Call.ADI


Mohawk Garnet
Mohawk Garnet™ – North American Hard Rock

Rough around the edges – which is what you want in your abrasive. More information at 1.866.642.7638 or info@mohawkgarnet.com


Graco Inc.
Blast with 92% less dust.

Graco EcoQuip Vapor Blast equipment performs as well as dry blasting, but reduces airborne dust up to 92%! Use less media, save money in material and cleanup. See our FREE shipping offer!


DeFelsko Corporation
PosiTector Dew Point Meter

Measures and records
environmental conditions
during surface prep and
painting. 4 Models
Available – Standard
or Advanced features,
Built-in or Separate probe.


Termarust Technologies
Termarust (HR CSA) Chemically Stops
Active Corrosion

Arch truss treated with Termarust's (HR CSA) in 2003. This steel arch bridge is rust free on all surfaces including the crevice corroded joints and connections.

 
 
 
Technology Publishing

The Technology Publishing Network

The Journal of Protective Coatings & Linings (JPCL) PaintSquare
Durability + Design Paint BidTracker JPCL Europe

 
EXPLORE:      JPCL   |   PaintSquare News   |   Interact   |   Buying Guides   |   Webinars   |   Resources   |   Classifieds
REGISTER AND SUBSCRIBE:      Free PaintSquare Registration   |   Subscribe to JPCL   |   Subscribe to PaintSquare News
MORE:      About PaintSquare.com   |   Privacy policy   |   Terms & conditions   |   Site Map   |   Search   |   Contact Us
 

© Copyright 2000-2014, Technology Publishing / PaintSquare, All rights reserved
2100 Wharton Street, Suite 310, Pittsburgh PA 15203-1951; Tel 1-412-431-8300; Fax 1-412-431-5428; E-mail webmaster@paintsquare.com