Where are errors most likely to occur when measuring dry film thickness on steel, and how can they be avoided?

More items for Quality Control


Selected Answers

From Christian Favennec of DCNS on April 23, 2014:
When a dry film thickness (DFT) is specified, it corresponds to the thickness of the paint over the peaks of the profile. DFT measurements on steel are generally performed with electromagnetic gauges. Parameters which can influence on the accuracy of the measurement include the profile of the substrate. If the calibration is done on a smooth plate, the profile of the surface s not taken into account in the measurement. ISO 19840 recommends a correction value (25 µm for medium profile, 40 µm for coarse profile). It means that if the NDFT is 100µm, the measurement must be done for 125 µm for a medium profile. The other method is to perform the calibration directly on the rough surface before paint application with the 2-points method, as also defined in the annex of ISO 19840. The profile is then correctly taken into account.  The magnetic properties of the steel can also influence the measurement. It is then recommended to perform the calibration on the same quality of steel, and a representative thickness. Edge effect cans also influence the measurement. This is why measurements are generally not performed less than 20 mm from an edge.  Ferritic or magnetic pigments in the paint can also influence the measurement, as the calibration is done on non-magnetic foils.

From PARVEZ SHAIKH of SANDVIK ASIA PVT. LTD. on August 2, 2013:
When calculating the DFT of a primer over a blasted surface, one has to ensure that the DFT meter is calibrated on the blasted surface itself to compensate for the BMR over the blasted surface. Also, the thickness measurement of coatings containing  micaceous iron oxide are sometimes not accurate.

Please sign in to submit your answer this question    

Tagged categories: Dry Film Thickness (DFT); Steel


Current PSF Question | Submit a PSF Question | Full PSF Archive

Advertisements
 
KTA-Tator, Inc. - Corporate Office
 
KTA-TATOR LABORATORY SERVICES
 
• Coating failure analysis
• Independent
  comparative testing
• Accelerated
  weathering testing
• Toxic metals testing
• A2LA Accredited
Contact: Cindy O'Malley,
at 412-788-1300 x180
 

 
HoldTight Solutions Inc.
 
NO FLASH RUST - NO CONTAMINANTS
 
Our HoldTight®102 salt remover & flash rust
preventer prevents flash
rust by removing surface contaminants. Contact us
for your nearest distributor.
(800) 319.8802 sales@holdtight.com
 

 
Detail Masters
 
Overspray Removal
 
We offer professional, turnkey service and unparalleled quality!
Our process can save hundreds— even thousands of dollars. It's fast, environmentally safe and 100% guaranteed.
 

 
SEMicro Division, M.E. Taylor Engineering, Inc.
 
Coatings Adhesion Testers
 
The PATTI® accurately measures the bond strength between coating & substrate. Outfitted properly, the surface can be rough, porous, or curved & >10K psi strong!
 

 
Fischer Technology Inc.
 
DUALSCOPE®FMP100 with DataCenter IP
 
Transfer customized inspection plans from PC to FMP100 using step-by-step guidance with prompts and pictures throughout the measurement procedure
 

 
DeFelsko Corporation
 
PosiTector SHD Shore Hardness Durometer
 
PosiTector SHD measures the hardness of non-metallic materials. Features a measurement timer, auto ignore mode and internal memory. Shore A or D available.
 

 
Absolute Equipment/Grand Rental Station
 
TIER 4 EQUIPMENT
 
We have Tier 4 Equipment including Air Compressors & Generators for Sale & Rent! Your job may now require Tier-4. www.absoluteequip.com or Call 412-931-6655.
 

 
RBW Enterprises, Inc.
 
Robotic Blasting and Painting
 
When using the FasterBlaster and FasterPainter, blasting and painting can be conducted simultaneously. View the video for a full explanation of the operation.
 

 
Atlantic Design, Inc.
 
ENGINEERING SOLUTIONS, NOT EXCUSES
 
See our website for features of our best seller, the ADI 3500CFM 4-Pot Blast Vacuum Recycler. A smaller package with all the ADI power you need. 866.Call.ADI
 

 
International Bridge Conference
 
2017 International Bridge Conference
 
June 4-8, 2017, National Harbor, Maryland
 

 
 
 

Technology Publishing Co., 2100 Wharton Street, Suite 310, Pittsburgh PA 15203-1951

TEL 1-412-431-8300  • FAX  1-412-431-5428  •  EMAIL webmaster@paintsquare.com


The Technology Publishing Network

Durability + Design PaintSquare the Journal of Protective Coatings & Linings Paint BidTracker

 
EXPLORE:      JPCL   |   PaintSquare News   |   Interact   |   Buying Guides   |   Webinars   |   Resources   |   Classifieds
REGISTER AND SUBSCRIBE:      Free PaintSquare Registration   |   Subscribe to JPCL   |   Subscribe to PaintSquare News
MORE:      About PaintSquare.com   |   Privacy policy   |   Terms & conditions   |   Site Map   |   Search   |   Contact Us