In your experience, what is the most common cause of premature coating failures?

More items for Quality Control
Answers Votes
Poor workmanship 76%
Incorrect specification 12%
Unforeseen exposure condition (due to design defect, for instance) 10%
Defective coating material 2%

Suggest a topic


Tagged categories: Coating failure

Comment from Glenn Summers, (8/25/2011, 6:36 AM)

Speaking only as it relates to concrete substrates; most specifications do not go far enough to insure that a concrete is properly treated, prior to the coating application. If a concrete is not "Stabilized" prior to coating, the Gel-Pore/Capillary system of the concrete will remain Open and Active to expell a concrete internal chemistry for years to come. Often, a specification is written to take in to account Harsh Service Environments as it relates to contaminates entering a concrete matrix from the exterior of a structure. It is one thing to attempt to protect a concrete by coating the exterior, but this type of specification falls short of a "Durable Surface". Great care and expense of sand blasting, high pressure washes and even acid etching will attempt to obtain longevity of a coating, but do not consider that an unstable concrete will allow moisture vapor to deposit chemicals underneath the best of coatings. When this internal chemistry and moisture migrates out to an atmosphere, coating failures are certain. A specification that doesn't address moisture travel In and Out of a concrete substrate will lead to a coating failure, not to mention all of the other deleterious events that occur to a concrete. When Carbonation is allowed to reduce the internal pH of a concrete below 11.5 pH, a coating loss is a minor problem compared to the corrosion cells that are now allowed to form on the reinforcing steel! At this point, "Another Coat of Paint Won't Help"!

Comment from Chuck Stevens, (8/31/2011, 12:18 PM)

It is extremely Important that the inspection attends the Pre-Job conference to discuss grey area's and how they should be addressed as agreed to by all involved

Comment Join the Conversation:

Sign in to our community to add your comments.

DeFelsko Corporation
PosiTector Inspection Kits

PosiTector 6000 Coating Thickness Gage easily converts to a surface profile gage, dew point meter or ultrasonic wall thickness gage with a simple probe change

HoldTight Solutions Inc.

Our HoldTight®102 salt remover & flash rust
preventer prevents flash
rust by removing surface contaminants. Contact us
for your nearest distributor.
(800) 319.8802

Novetas Solutions
Abrasive Blasting near or over water?

100% Recycled Glass! NO Arsenic, Beryllium or other Toxic Metals! Great White Metal Finish and Safer than Slags! Call us at 866-775-6226

Desco Mfg. Co., Inc.

Steel Fabrication

• Shipyards
• Plate Fabrication
• Structural Steel
• Maintenance

DESCO Mfg.Co., Inc.

Fischer Technology Inc.
DUALSCOPE®FMP100 with DataCenter IP

Transfer customized inspection plans from PC to FMP100 using step-by-step guidance with prompts and pictures throughout the measurement procedure

KTA-Tator, Inc. - Corporate Office

• Coating failure analysis
• Independent
  comparative testing
• Accelerated
  weathering testing
• Toxic metals testing
• A2LA Accredited
Contact: Cindy O'Malley,
at 412-788-1300 x180

Novatek Corporation
Novatek Corporation, Dustless Coatings Removal

Strip, clean and profile all dust free! Comply with new lead standards. Contact today: (866) 563-7800

CS Unitec
Remove Rust, Paint and More!

Remove coatings, corrosion & produce keyed surfaces with CS Unitec's floor planers. 8" & 10" cutting width. Gas, air & electric models.

N.T. Ruddock Co.

Our Abrasives Hold Up Under Pressure

N. T. Ruddock focuses on abrasive selection, equipment evaluation, equipment maintenance & reduction of abrasive consumption. Other services include Screen Analysis & Background Radiation Testing.

Dampney Co., Inc.
Temperature Indicating Paint/Coating

protective coating that provide a visual warning that a pipe, vessel, reactor, transfer line, and similar equipment is overheating due to failure of refractory linings or the bypassing of hot gasses.

Technology Publishing

The Technology Publishing Network

The Journal of Protective Coatings & Linings (JPCL) PaintSquare
Durability + Design Paint BidTracker

EXPLORE:      JPCL   |   PaintSquare News   |   Interact   |   Buying Guides   |   Webinars   |   Resources   |   Classifieds
REGISTER AND SUBSCRIBE:      Free PaintSquare Registration   |   Subscribe to JPCL   |   Subscribe to PaintSquare News
MORE:      About   |   Privacy policy   |   Terms & conditions   |   Site Map   |   Search   |   Contact Us

© Copyright 2000-2016, Technology Publishing / PaintSquare, All rights reserved
2100 Wharton Street, Suite 310, Pittsburgh PA 15203-1951; Tel 1-412-431-8300; Fax 1-412-431-5428; E-mail