In your experience, what is the most common cause of premature coating failures?

More items for Quality Control
Answers Votes
Poor workmanship 76%
Incorrect specification 12%
Unforeseen exposure condition (due to design defect, for instance) 10%
Defective coating material 2%

Suggest a topic


Tagged categories: Coating failure

Comment from Glenn Summers, (8/25/2011, 6:36 AM)

Speaking only as it relates to concrete substrates; most specifications do not go far enough to insure that a concrete is properly treated, prior to the coating application. If a concrete is not "Stabilized" prior to coating, the Gel-Pore/Capillary system of the concrete will remain Open and Active to expell a concrete internal chemistry for years to come. Often, a specification is written to take in to account Harsh Service Environments as it relates to contaminates entering a concrete matrix from the exterior of a structure. It is one thing to attempt to protect a concrete by coating the exterior, but this type of specification falls short of a "Durable Surface". Great care and expense of sand blasting, high pressure washes and even acid etching will attempt to obtain longevity of a coating, but do not consider that an unstable concrete will allow moisture vapor to deposit chemicals underneath the best of coatings. When this internal chemistry and moisture migrates out to an atmosphere, coating failures are certain. A specification that doesn't address moisture travel In and Out of a concrete substrate will lead to a coating failure, not to mention all of the other deleterious events that occur to a concrete. When Carbonation is allowed to reduce the internal pH of a concrete below 11.5 pH, a coating loss is a minor problem compared to the corrosion cells that are now allowed to form on the reinforcing steel! At this point, "Another Coat of Paint Won't Help"!

Comment from Chuck Stevens, (8/31/2011, 12:18 PM)

It is extremely Important that the inspection attends the Pre-Job conference to discuss grey area's and how they should be addressed as agreed to by all involved

Comment Join the Conversation:

Sign in to our community to add your comments.

Elcometer, Inc.
Elcometer 106 Pull-Off Adhesion Tester

Portable, easy to operate; Provides numerical value for adhesion; Comes in carrying case - Ideal for site tests; No power supply necessary.

Fischer Technology Inc.
DUALSCOPE®FMP100 with DataCenter IP

Transfer customized inspection plans from PC to FMP100 using step-by-step guidance with prompts and pictures throughout the measurement procedure

Graco Inc.
Graco Mortar Pump

The M680 sprays epoxy-based mortars, anti-skid coatings, cementitious and filled materials. Compact.
Easy to use.
Call 877-844-7226 or

Nationwide Overspray
Profession Overspray Removal Services

The Finest Name in Safe Overspray Removal. We specialize in removing all contaminants from any surface. Family Owned and Operated for 33 years! Fully insured. Satisfaction is guaranteed.

KTA-Tator, Inc. - Corporate Office

• Coating failure analysis
• Independent
  comparative testing
• Accelerated
  weathering testing
• Toxic metals testing
• A2LA Accredited
Contact: Kevin Brown,
at 336-386-4000

DeFelsko Corporation
A Smart New Way to Measure

PosiTector SmartLink and free mobile app turns your cell phone or tablet into a virtual PosiTector gage.

Wasser High-Tech Coatings Inc.
Wasser Coatings Protect

Wasser Coatings offer a complete range of Moisture Cure Urethane (NEPCOAT approved) systems in addition to Polyurea membranes and linings(NSF).

Larson Electronics
Larson Electronics Explosion Proof Tank Lighting

Larson Electronics is a premium supplier and manufacturer of portable explosion proof lighting systems for tank cleaning and servicing lighting.

SAFE Systems, Inc.
Custom blast rooms
by SAFE Systems

Don't waste time and money "making do" with a "standard" design. Let us work with you to design and build the
system that best fits
your requirements.
Call 1-800-634-7278

RPB Respiratory

With RPB Safety’s new Nova 3 Cassette Lens System which has been specifically designed to save you time and money! See the benefits for yourself now!

Technology Publishing

The Technology Publishing Network

The Journal of Protective Coatings & Linings (JPCL) PaintSquare
Durability + Design Paint BidTracker

EXPLORE:      JPCL   |   PaintSquare News   |   Interact   |   Buying Guides   |   Webinars   |   Resources   |   Classifieds
REGISTER AND SUBSCRIBE:      Free PaintSquare Registration   |   Subscribe to JPCL   |   Subscribe to PaintSquare News
MORE:      About   |   Privacy policy   |   Terms & conditions   |   Site Map   |   Search   |   Contact Us

© Copyright 2000-2015, Technology Publishing / PaintSquare, All rights reserved
2100 Wharton Street, Suite 310, Pittsburgh PA 15203-1951; Tel 1-412-431-8300; Fax 1-412-431-5428; E-mail