In your experience, what is the most common cause of premature coating failures?

More items for Quality Control
Answers Votes
Poor workmanship 76%
Incorrect specification 12%
Unforeseen exposure condition (due to design defect, for instance) 10%
Defective coating material 2%


Suggest a topic

   

Tagged categories: Coating failure

Comment from Glenn Summers, (8/25/2011, 6:36 AM)

Speaking only as it relates to concrete substrates; most specifications do not go far enough to insure that a concrete is properly treated, prior to the coating application. If a concrete is not "Stabilized" prior to coating, the Gel-Pore/Capillary system of the concrete will remain Open and Active to expell a concrete internal chemistry for years to come. Often, a specification is written to take in to account Harsh Service Environments as it relates to contaminates entering a concrete matrix from the exterior of a structure. It is one thing to attempt to protect a concrete by coating the exterior, but this type of specification falls short of a "Durable Surface". Great care and expense of sand blasting, high pressure washes and even acid etching will attempt to obtain longevity of a coating, but do not consider that an unstable concrete will allow moisture vapor to deposit chemicals underneath the best of coatings. When this internal chemistry and moisture migrates out to an atmosphere, coating failures are certain. A specification that doesn't address moisture travel In and Out of a concrete substrate will lead to a coating failure, not to mention all of the other deleterious events that occur to a concrete. When Carbonation is allowed to reduce the internal pH of a concrete below 11.5 pH, a coating loss is a minor problem compared to the corrosion cells that are now allowed to form on the reinforcing steel! At this point, "Another Coat of Paint Won't Help"!


Comment from Chuck Stevens, (8/31/2011, 12:18 PM)

It is extremely Important that the inspection attends the Pre-Job conference to discuss grey area's and how they should be addressed as agreed to by all involved


Comment Join the Conversation:

Sign in to our community to add your comments.

Advertisements
 
Fischer Technology Inc.
 
DUALSCOPE®FMP100 with DataCenter IP
 
Transfer customized inspection plans from PC to FMP100 using step-by-step guidance with prompts and pictures throughout the measurement procedure
 

 
DeFelsko Corporation
 
PosiTest LPD Low voltage Pinhole Detector
 
Uses a wet sponge to detect holidays, pinholes and other discontinuities on metal and concrete substrates. Easy to use ergonomic design and 4 voltage outputs.
 

 
SEMicro Division, M.E. Taylor Engineering, Inc.
 
Coatings Adhesion Testers
 
The PATTI® accurately measures the bond strength between coating & substrate. Outfitted properly, the surface can be rough, porous, or curved & >10K psi strong!
 

 
Industrial Vacuum Equipment Corp.
 
Hurricane Vacuums
& Dust Collectors
 
Vacuum and dust collector hose, filters and related accessories.
IndustrialVacuum.com
 

 
HoldTight Solutions Inc.
 
NO FLASH RUST - NO CONTAMINANTS
 
Our HoldTight®102 salt remover & flash rust
preventer prevents flash
rust by removing surface contaminants. Contact us
for your nearest distributor.
(800) 319.8802 sales@holdtight.com
 

 
KTA-Tator, Inc. - Corporate Office
 
KTA-TATOR LABORATORY SERVICES
 
• Coating failure analysis
• Independent testing
• Accelerated weathering testing
• Abrasives Testing
• Oil & Gas Material Qualification
• A2LA Certificate #2455.01
Contact: Rob Leggat
at 412-788-1300 x176
 

 
Sherwin-Williams
 
Sherwin-Williams Protective & Marine Coatings
 
With 4,000 distribution points and 3,700+ years of combined experience, Sherwin-Williams delivers the products, support and expertise you need, right where you need it.
 

 
Axxiom Manufacturing
 
Schmidt Introduces
the New miniBRS
 
Reduced in size, it is incredibly easy to maneuver and operate! The perfect alternative to larger blast & recovery units when project space is limited.
Call 1-800-231-2085
 

 
Carboline Company
 
History. Service. Innovation.
 
We are a global leader in coatings, linings, and fireproofing. We have the right people, right products, and right locations.
 

 
Safway Services
 
Safeguard Assets. Ensure Productivity. HAKI®
 
Protect assets and equipment. Keep facilities open and operational. Maintain schedules regardless of weather. Ensure smooth and continuous production. Easy to erect. Safway is the primary distributor of HAKI® products including HAKISPAN and HAKITEC® 750 – in North America.
 

 
 
 

Technology Publishing Co., 1501 Reedsdale Street, Suite 2008, Pittsburgh, PA 15233

TEL 1-412-431-8300  • FAX  1-412-431-5428  •  EMAIL webmaster@paintsquare.com


The Technology Publishing Network

Durability + Design PaintSquare the Journal of Protective Coatings & Linings Paint BidTracker

 
EXPLORE:      JPCL   |   PaintSquare News   |   Interact   |   Buying Guides   |   Webinars   |   Resources   |   Classifieds
REGISTER AND SUBSCRIBE:      Free PaintSquare Registration   |   Subscribe to JPCL   |   Subscribe to PaintSquare News
MORE:      About PaintSquare.com   |   Privacy policy   |   Terms & conditions   |   Site Map   |   Search   |   Contact Us