PaintSquare.com


The First Word in Protective & Marine Coatings

A Product of Technology Publishing / PaintSquare
JPCL | PaintSquare News | Durability + Design | Paint BidTracker

Resource Guide Extreme Temperatures

Paint and Coatings Industry News

Main News Page


Lab Corrosion Test Tougher Than Field

Tuesday, November 23, 2010

Comment | More

Tnemec has developed a 28-day accelerated lab coatings and linings testing protocol that the company says is more aggressive than 365 days of exposure in the severe headspace environment of a manhole in Texas.

That conclusion follows a year-long Field Correlation Study of the barrier performance of protective coatings and linings against wastewater corrosion, says Tnemec, the Kansas City, MO-based manufacturer of protective coatings and linings.

“The corrosion protection of steel and concrete by a protective coating or lining may be altered by exposure to sewer gases and by the composition of the corrosive reagents found in headspace environments of domestic wastewater conveyance and treatment structures,” according to the study, written by Vaughn O’Dea, director of Sales, Water and Wastewater Treatment, and Remi Briand, vice president, Research & Development.

S.W.A.T. Testing

Tnemec worked with wastewater experts, protective coatings formulators, and testing agencies to develop the testing protocol. The goal was “to quantifiably evaluate the performance qualities of protective coatings and linings recommended for use in severe wastewater headspace environments,” the study said.

The laboratory test method, known as The Standard Practice for Rapid Evaluation of Coatings and Linings by Severe Wastewater Analysis Test (S.W.A.T.), simulates a severe wastewater headspace condition.

Coated steel and concrete samples are wetted with a corrosive solution and then exposed to hydrogen sulfide (H2S), a gas known to alter barrier properties of protective coatings and linings. The test is performed under controlled conditions in an airtight chamber with a constant temperature of 150° F.

Specimens are immersed into the aqueous solutions three times daily for a period of 15 minutes, then exposed to the sewer gas the balance of the time. The cyclic exposure continues for a period of 28 days.

Multiple Testing Sites

The field study was performed at seven testing sites, including a manhole located along a drainage ditch in a mixed residential and industrial area of Texas, using similar protective linings and testing methods performed in accordance with the S.W.A.T. protocol.

The Texas site was chosen because of its highly corrosive environment and elevated hydrogen sulfide levels (>500 ppm). Six steel coupons and six concrete cylinder coupons were properly prepared, coated with protective coating systems commonly used for wastewater corrosion protection, and exposed to the severe headspace environment of the manhole for 365 days, the company said.

tnemec_photo1

Photos: Tnemec

The Texas testing site was chosen for its highly corrosive environment and elevated hydrogen sulfide levels.

Researchers used electrochemical impedance spectroscopy (EIS) analysis to test the coated steel samples for permeation resistance.

“Any polymer degradation is easily detected by a decrease in the measured impedance,” the study said. “When interpreting permeation resistance using EIS, the higher and more stable the retained impedance following exposure, the better the long-term permeability resistance and, therefore, the better the long-term coating performance.”

ASTM Methods Employed

Researchers also performed physical testing and visual inspection of samples in accordance with various American Society for Testing and Materials (ASTM) methods before and after exposure to S.W.A.T.

“Polymers that retain their physical properties, such as adhesion, tensile strength and flexural properties, under such corrosive conditions are assumed to offer better substrate protection within severe wastewater environments,” the study said.

It added: “Protective coatings should not blister, check, crack, or allow corrosion of the substrate when exposed to severe wastewater environments. Polymers that retain film quality are assumed to offer better substrate protection.”

Coatings Performance Results

Steel panels coated with a polyamide epoxy and a polyamide epoxy coal-tar exhibited blistering and a major drop in EIS readings in both the field study and the S.W.A.T. testing, the study found.

Panels coated with a two-component, 100% solids aromatic polyurethane hybrid and a three-component, 100% solids polyamine epoxy mortar exhibited no blistering, visible pinpoint rusting, or any other film defect and only a slight drop in EIS readings in both the field study and S.W.A.T.

The steel panel coated with a fiber-reinforced polyamine epoxy exposed to the 28-day S.W.A.T. showed a decrease in permeation at 10 days, followed by a recovery of permeation resistance at 28 days, compared to no drop in permeation in the less aggressive field environment.

The steel panel coated with a novolac epoxy showed cracking and zero permeation resistance after exposure to the aggressive 28-day S.W.A.T. environment, compared to a minimal loss of film quality and permeation resistance based on results from the field study.

tnemec_photo2
Physical testing was performed in accordance with relevant ASTM methods.

Cross sections of the concrete test samples were microscopically measured for discoloration of the film, which is an indication of sewer gas penetration.

Concrete coupons coated with polyamide epoxy and novolac epoxy exhibited blistering in the field study, which is consistent with what happens with these coatings in S.W.A.T. Panels coated with a two-component, 100% solids fiber-reinforced polyamine epoxy, a three-component, 100% solids polyamine epoxy mortar, and an aromatic polyurethane hybrid exhibited no blistering or any other film defects. A bare concrete coupon exhibited corrosion similar to 28-day S.W.A.T.

Simulating ‘Sewer Air’

The S.W.A.T. has been restricted to simulations that exemplify the application of the “sewer air components” that were known to affect protective coating systems. The "sewer air" was comprised of H2S, due to available data on gases that commonly emanate from septic sewages flowing in typical collection systems.

“Until now, analytical data for ‘sewer gases’ appear to have been derived mainly by inference from information surrounding sewage decomposition, rather than from studies of air in contact with flowing sewage,” the report added. “The data surrounding the sewer gases collected from this study will facilitate gas modeling and future incorporation into the S.W.A.T. protocol to closer replicate sewer headspace environments.”

Other testing sites in the study included North Central Florida, Northwestern U.S., New England, Rocky Mountain U.S., coastal Virginia and Midwestern U.S. These sites were chosen based on their histories of biogenic sulfide corrosion and their different climates.

   

Tagged categories: Performance testing; Tnemec; Wastewater Plants

Comment from Larry Muzia, (11/29/2010, 9:16 AM)

The testing may well be accurate, however, one must recognize that both environmental and substrate conditions must also be a factor in deciding which is best. We recently had a bad experience with installing an plural sprayed aromatic urethane in a high H2S environment. Work being done under live flow made it impossible to control H2S levels. After several attempts to install, the project team decided to switch to a fast set epoxy to protect the concrete overhead. To date, the epoxy is doing what the aromatic urethane could not. The manufacturer did endorse the change from urethane to epoxy after understanding the limitations and yes humidity levels were constantly around 85%.It is important to understand that resin technology is one piece of the equation another piece just as critical is environmental conditions during applications.


Comment Join the Conversation:

Sign in to our community to add your comments.

Corrosion Probe, Inc.
From Detection to Correction

Corrosion Probe, Inc. has the Most Concrete Coatings Experience and Expertise. Contact us today at
860-767-4402, www.cpiengineering.com


Minerals Research & Recovery

HIGH PERFORMANCE ABRASIVES


“Made in the USA!”

Why recycle waste from other countries? Go FASTER, CLEANER, at 1/3 THE COST with MR&R “All-American” Sharpshot®HP!!

WATCH THE VIDEO


Termarust Technologies
Termarust (HR CSA) Chemically Stops
Active Corrosion

Hydro Utility Penstock Overcoated in 1997. Was power washed and overcoated with major cost saving. No environmental impact with Termarust's low LC50 of 41,007 ppm.


Abrasives Inc.
Check our Prices for Blast Abrasives

Faced with higher abrasive costs? We invite you to call & check our rates on Black Magic® coal slag and other quality blast materials. Abrasives Inc. 800-584-7524


CESCO
PRESSURE WASHERS

• 10,000 PSI
• Electric or diesel models
• Buy or rent from CESCO
• Lease Financing Available
CESCO is your One Stop
Corrosion
Shop
Contact us: 888-772-3726
BlastandPaint.com


Industrial Vacuum Equipment Corp.
Hurricane Vacuums
& Dust Collectors

Vacuum and dust collector hose, filters and related accessories.
IndustrialVacuum.com


Elcometer, Inc.
Durability & Design meet
Performance & Reliability

Elcometer 319 Dewpoint Meter
View the technical data on the Elcometer Dewpoint meter.

 
 
 
Technology Publishing

The Technology Publishing Network

The Journal of Protective Coatings & Linings (JPCL) PaintSquare
Durability + Design Paint BidTracker JPCL Europe

 
EXPLORE:      JPCL   |   PaintSquare News   |   Interact   |   Buying Guides   |   Webinars   |   Resources   |   Classifieds
REGISTER AND SUBSCRIBE:      Free PaintSquare Registration   |   Subscribe to JPCL   |   Subscribe to PaintSquare News
MORE:      About PaintSquare.com   |   Privacy policy   |   Terms & conditions   |   Site Map   |   Search   |   Contact Us
 

© Copyright 2000-2014, Technology Publishing / PaintSquare, All rights reserved
2100 Wharton Street, Suite 310, Pittsburgh PA 15203-1951; Tel 1-412-431-8300; Fax 1-412-431-5428; E-mail webmaster@paintsquare.com