CA Eyes Major Lead Level Changes

Thursday, June 12, 2014

More items for Health & Safety

Comment | More

California regulators are moving closer to slashing lead exposure limits for workers, calling the current standards outdated and harmful to human health.

The California Division of Occupational Safety and Health (Cal/OSHA) has issued draft discussion changes for both general industry and construction standards that would cut permissible exposure limits (PELs) by five times their current level and blood lead levels by up to six times.

The proposed revisions are for discussion only and are not a rulemaking proposal, Cal/OSHA noted.

The desire to update state's lead standards has generated years of discussion between the California Department of Public Health and Cal/OSHA. Current rules reflect toxicity information that is more than 30 years old, officials say.

"Current medical information clearly demonstrates harmful effects of chronic and low-level exposure to lead in adults, at levels well below those currently allowed by the standards," the CDPH noted in its recommendations for improving the state's standards.

Cal/OSHA lead standards
OSHA

California officials are discussing changes to construction and general industry lead standards to reduce worker exposure and lower blood lead levels.

Cal/OSHA is holding an advisory meeting at 9:30 a.m. PT today (June 12) in Oakland, CA, to give stakeholders an opportunity to provide feedback on proposed revisions to the lead standards.

Changing the PEL

According to a summary of changes, the draft discussion proposes permissible exposure limit of 10 µg/m3 (currently 50 µg/m3) and an action level of 2 µg/m3 (currently 30 µg/m3) averaged over an eight-hour period.

These limits are necessary to maintain blood lead levels below 10 micrograms per deciliter of blood (µg/dL), the CDPH said.

The CDPH Occupational Lead Poisoning Prevention Program reviewed scientific information and made health-based recommendations to Cal/OSHA for revising its current General Industry Lead Standard and Lead in Construction Standard.

CDPH first recommended changes to Cal/OSHA in 2011 for construction standards and in 2010 for general industry standards; the changes included lowering the PEL to 0.5-2.1 µg/m3 over and eight-hour workday.

Public health agencies have recommended that BLLs be maintained below this level over a working lifetime to avoid reproductive problems and longterm damage to target organs.

However, current standards allow BLLs up to 50-60 µg/dL before workers have to be removed from significant lead exposure.

"We know this level is harmful to health," CDPH stated.

Increased Testing

The draft discussion includes changes to BLL testing protocols and frequency. Employers would offer initial testing, followed by testing every two months for the first six months of employment, and then every six months after that. Currently, this is required only by the construction standard.

If an employee's BLL is 10 µg/dL or higher, it would trigger continued testing every two months—something currently required at a BLL of 40 µg/dL—and monthly testing would be required at levels of 20 µg/dL, which is currently required for those on medical removal protection.

Employers would be required to investigate any BLL at or above 10 µg/dL and correct any workplace factors that contributed to the elevated levels.

PEL lead
EPA

"Current medical information clearly demonstrates harmful effects of chronic and low-level exposure to lead in adults, at levels well below those currently allowed by the standards," the California Department of Public Health said.

Testing for zinc protoporphyrin would not be required unless the employee's BLL was 20 µg/dL or higher.

Currently, employees in general industry must be placed on medical removal protection if the average of their last three BLL tests is 50 µg/dL or higher; in construction, employees are removed if their last two BLLs average 50 µg/dL or more. The draft proposes placing workers on medical removal protection if their BLLs are above 20 µg/dL for two tests spaced one month apart, or a single BLL of 30 µg/dL or higher.

Focus on Reproductive Health

Under the draft proposal, employee training would highlight the vulnerability of reproductive health to low-level lead exposure and the importance of medical consultation. Protecting reproductive health would be listed as a factor to consider in any physician-recommended special protective measures.

The draft would require that food and beverages are kept out of work areas and hand washing facilities are available.

For the general industry, altering or disturbing lead for over eight hours during any 30-day period would trigger the same protections currently given to employees with exposure over the action level.

Employers would also be required to provide protective clothing, changing rooms, clean eating areas and signs to employees performing threshold work.

   

Tagged categories: Certifications and standards; Construction; Health and safety; Lead; OSHA

Comment Join the Conversation:

Sign in to our community to add your comments.

Advertisements
 
Bullard
 
Upgrade with the Bullard GenVX
 
Click here to learn how you can get a GenVX Helmet and Win.
 

 
Detail Masters
 
Overspray Removal
 
We offer professional, turnkey service and unparalleled quality!
Our process can save hundreds— even thousands of dollars. It's fast, environmentally safe and 100% guaranteed.
 

 
SAFE Systems, Inc.
 
Custom blast rooms
by SAFE Systems
 
Don't waste time and money "making do" with a "standard" design. Let us work with you to design and build the system that best fits your requirements.
Call 1-800-634-7278
 

 
Clemco Industries Corp.
 
Maximum Dust Suppression Systems Start at $14,950
 
The system comprises proven technology and equipment with user-friendly flexibility in mind. See it in action.
 

 
US Minerals
 
Hit Harder. Clean Faster.
 
Black Diamond abrasive products are the toughest, most effective blasting media and supply the superior power you need to get any job done.
 

 
SSPC: The Society for Protective Coatings
 
http://www.sspc.org/
 
Join SSPC and Enhance
Your Career !
 

 
Blastox/The TDJ Group, Inc.
 
Blastox® - One Step Lead Abatement
 
Sandblast additive delivered to jobsite pre-blended to eliminate hazardous abrasive wastes. Why mix, meter or apply at the job-site? Blast with ease and
Let your painters paint!
1(800)-252-7869
 

 
Polygon
 
POLYGON - Temporary Humidity Control
 
We specialize in innovative climate control solutions for industrial painting, utilizing alternative energy sources and combining desiccants with heating or cooling.
 

 
Tarps manufacturing, Inc.
 
QUALITY MADE IN AMERICA —Available near you!
 
CLICK to get a behind-the-scenes look at how Tarps Manufacturing makes the highest-quality tarps right here in the USA — available nationwide.
 

 
PreTox Products - NexTec, Inc.
 
GOT LEAD? Specify Pretox System products
 
The ONLY Lead Stabilizer Compatible with All Paint Removal Methods. Works with all Blast Media: Grits | Recyclable Abrasives | CO2 | Water | Power Tools | Etc. Call Dave Steffen at 800.338.8296.
 

 
 
 

Technology Publishing Co., 2100 Wharton Street, Suite 310, Pittsburgh PA 15203-1951

TEL 1-412-431-8300  • FAX  1-412-431-5428  •  EMAIL webmaster@paintsquare.com


The Technology Publishing Network

Durability + Design PaintSquare the Journal of Protective Coatings & Linings Paint BidTracker

 
EXPLORE:      JPCL   |   PaintSquare News   |   Interact   |   Buying Guides   |   Webinars   |   Resources   |   Classifieds
REGISTER AND SUBSCRIBE:      Free PaintSquare Registration   |   Subscribe to JPCL   |   Subscribe to PaintSquare News
MORE:      About PaintSquare.com   |   Privacy policy   |   Terms & conditions   |   Site Map   |   Search   |   Contact Us